To use a CTA
or TFC membrane, the feed water must be microbiologically safe with
the following limits:
Iron -
0.1 mg/l, Manganese - 0.05 mg/l, Hydrogen Sulfide -
0 mg/l, Tannins - 0 mg/l
The
difference between nominal and absolute membrane ratings
- Nominal
Ratings
- If a membrane
(or filter for that matter) has a nominal rating, it means that
the tests that have been preformed on that membrane (or filter)
have been within the stated range 85% - 90% of the time.
- Absolute
Ratings
- If a membrane
(or filter for that matter) has an absolute rating, it means that
the tests that have been preformed on that membrane (or filter)
have been within the stated range 95% - 99% of the time.
Below
are some of the differences between a CTA and TFC membranes. The statistics
are based on nominal membrane ratings.
|
Characteristic
|
CTA
Membrane
|
TFC
Membrane
|
| Product
water rate (to atmosphere @ 60 psi, 77 degrees Feranheit) |
22
gpd
|
24
- 35 gpd
|
| Maximum
feed water TDS (with sufficient line pressure) |
1200
mg/l
|
2000
mg/l
|
| Maximum
feed water hardness |
10gpg
|
10
gpg
|
| Rejection
of TDS |
88%
- 93%
|
95%
- 98%
|
| Feed
water temperature |
40
°F - 86 °F
4
°C - 30 °C
|
40
°F - 113 °F
4
°C - 45 °C
|
| Feed
water pH |
3.0
- 9.0
|
2.0
- 11.0
|
| Maximum
feed pressure (in suitable pressure vessel) |
50
- 100 psi
|
50
- 100 psi
|
| Booster
pump pressure |
80
psi
|
80
psi
|
| Chlorine
tolerance |
excess
of 10000 mgl
|
sensitive
to chlorine & other oxidizers.
|
Nominal Membrane
Rejections Performances*
|
Inorganic
Contaminant
|
CTA
membrane
|
TFC
membrane
|
Inorganic
Contaminant
|
CTA
membrane
|
TFC
membrane
|
|
Aluminum
|
90-95%
|
93-98%
|
Magnesium
|
90-95%
|
93-98%
|
|
Arsenic
|
90-95%
|
98-98%
|
Manganese
2
|
90-95%
|
93-98%
|
|
Barium
|
90-95%
|
98-95%
|
Mercury
|
90-95%
|
93-98%
|
|
Bicarbonate
|
85-90%
|
90-95%
|
Nickel
|
90-98%
|
93-98%
|
|
Boron
|
30-40%
|
55-60%
|
Nitrate
3
|
40-50%
|
85-90%
|
|
Cadmium
|
90-95%
|
93-98%
|
Phosphate
|
90-95%
|
93-98%
|
|
Calcium
|
90-95%
|
93-98%
|
Potassium
|
85-90%
|
90-95%
|
|
Chloride
|
85-90%
|
90-95%
|
Radioactivity
|
90-95%
|
93-98%
|
|
Chromate
|
85-90%
|
90-95%
|
Selenium
|
90-95%
|
93-98%
|
|
Chromium
|
90-95%
|
93-98%
|
Silver
|
90-95%
|
93-98%
|
|
Copper
|
90-95%
|
93-98%
|
Sodium
|
85-90%
|
90-95%
|
|
Cyanide
|
85-90%
|
90-95%
|
Strontium
|
90-95%
|
93-98%
|
|
Fluoride
|
85-90%
|
90-95%
|
Sulfate
|
90-95%
|
93-98%
|
|
Iron
2
|
90-95%
|
93-98%
|
Zinc
|
90-95%
|
93-98%
|
|
Lead
|
90-95%
|
93-98%
|
|
|
*Based
on reverse osmosis membranes producing to atmosphere with 60
psi net pressure and 77 degrees Fahrenheit.
|
|